Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
J. vasc. bras ; 20: e20200230, 2021. tab, graf
Article in English | LILACS | ID: biblio-1340170

ABSTRACT

Abstract Background Surgical management of patients with abdominal aortic diseases associated with distal narrowing is a challenging situation. Objectives To evaluate outcomes of unibody bifurcated endovascular stent graft repair. Methods This is a retrospective, observational, multi-institutional database study of a cohort of consecutive cases, approved by the local Ethics Committee. Records were reviewed of patients diagnosed from 2010 to 2020 with "shaggy" aorta, saccular aneurysm, penetrating aortic ulcer, and isolated aortic dissection located in the infrarenal abdominal aorta. All patients were treated with a unibody bifurcated stent graft. Main outcomes were technical success, procedure complications, long-term patency, and mortality in the follow-up period up to 5 years. Data on demographics, comorbidities, surgical management, and outcomes were analyzed. Results Twenty-three patients were treated with unibody bifurcated stent graft repair, including 7 cases of "shaggy" aorta, 3 isolated dissections of the abdominal aorta, 4 penetrating aortic ulcers, and 9 saccular aneurysms. Immediate technical success was achieved in 100% of cases. At follow-up, all stent grafts remained patent and there were no limb occlusions. The patients were symptom-free and reported no complications related to the procedure. There were 5 deaths during the follow-up period (median= 4 years), but none were related to the procedure and there were no aorta-related deaths. Conclusions The present study shows that unibody bifurcated stent grafting is safe and effective in this group of patients with narrow distal abdominal aorta and complex aortic pathology. The results were similar for both infrarenal aortic aneurysms and aorto-iliac atherosclerotic disease.


Resumo Contexto O manejo cirúrgico de pacientes com doenças da aorta abdominal associadas ao estreitamento distal é desafiador. Objetivos Avaliar os desfechos do reparo endovascular com endoprótese bifurcada do tipo monobloco. Métodos Foi realizado um estudo retrospectivo, de coorte observacional, de banco de dados multi-institucional, com casos consecutivos, após aprovação pelo Comitê de Ética local. Foram analisados prontuários de pacientes com diagnóstico de shaggy aorta, aneurisma sacular, úlcera penetrante da aorta e dissecção isolada da aorta localizados na aorta abdominal infrarrenal entre 2010 e 2020; todos os pacientes foram tratados com endoprótese bifurcada do tipo monobloco. Os principais desfechos foram sucesso técnico, complicações relacionadas ao procedimento, perviedade de longo prazo e mortalidade no seguimento de até 5 anos. Foram incluídos dados demográficos, comorbidades, manejo cirúrgico e desfechos. Resultados Vinte e três pacientes foram tratados com endoprótese bifurcada do tipo monobloco, incluindo 7 casos de shaggy aorta, 3 dissecções isoladas da aorta abdominal, 4 úlceras penetrantes da aorta e 9 aneurismas saculares. Sucesso técnico imediato foi obtido em 100% dos casos. No seguimento, todas as endopróteses permaneceram pérvias e não houve oclusões de membros. Os pacientes estavam sem sintomas e não relataram complicações relacionadas ao procedimento. Ocorreram 5 óbitos durante o seguimento (mediana = 4 anos), mas nenhum relacionado ao procedimento ou à aorta. Conclusões O presente estudo mostra que a endoprótese bifurcada do tipo monobloco é segura e eficaz neste grupo de pacientes com estreitamento distal da aorta abdominal e patologia aórtica complexa. Os resultados foram semelhantes para aneurismas da aorta infrarrenal e doença aterosclerótica aortoilíaca.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/surgery , Endovascular Procedures/methods , Aortic Dissection/surgery , Aorta, Abdominal , Prostheses and Implants , Retrospective Studies , Endovascular Procedures/instrumentation , Endovascular Procedures/rehabilitation
2.
J. vasc. bras ; 18: e20180040, 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-990123

ABSTRACT

O tromboembolismo venoso (TEV) é uma doença silenciosa e potencialmente letal que acomete parcela importante dos pacientes hospitalizados. Com alta morbimortalidade e elevado custo financeiro para o sistema de saúde, o TEV pode ser prevenido com uso da profilaxia, já estabelecida pela literatura. No mundo real, a profilaxia para TEV possui média de adequação inferior a 50%. Objetivos Definir o perfil epidemiológico do doente com TEV em um hospital universitário e a taxa de adequação da profilaxia para TEV no referido serviço, além de determinar meios para melhorá-la. Métodos Estudo transversal observacional realizado pela coleta de dados no prontuário médico dos pacientes que preencheram critérios de inclusão. Comparou-se a taxa de adequação da profilaxia para TEV prescrita para pacientes clínicos e cirúrgicos, segundo diretrizes da Sociedade Brasileira de Angiologia e Cirurgia Vascular (SBACV), de acordo com sua classificação de risco para TEV. Resultados A taxa global de adequação das prescrições de profilaxia para TEV foi de 42,1% versus 57,9% de inadequação. Pacientes clínicos obtiveram taxa de adequação de 52,9%, enquanto pacientes cirúrgicos obtiveram taxa de adequação de 37,5%. Conclusões As taxas de prescrição adequada para profilaxia para TEV ainda se encontram aquém do esperado. Educação continuada, estímulo à aplicação da estratificação de risco à beira do leito e adequações no sistema de prescrição eletrônica podem aumentar as taxas de prescrição adequada para profilaxia de TEV


Venous thromboembolism (VTE) is a silent and potentially lethal disease that affects a considerable proportion of hospitalized patients. It has high morbidity and mortality and is responsible for a heavy financial burden on healthcare systems. However, VTE can be prevented using prophylaxis measures that have been established in the literature. Nonetheless, in the real world, mean rates of appropriately administered VTE prophylaxis are lower than 50%. Objectives To define the epidemiological profile of patients with VTE in a University Hospital and the rate of appropriately administered VTE prophylaxis at that service and to identify measures to improve the rate. Methods A cross-sectional, observational study was conducted with data collected from the medical records of patients who met the inclusion criteria. The rates of correct VTE prophylaxis prescribed to clinical and surgical patients were compared, assessed according to guidelines published by the Brazilian Society of Angiology and Vascular Surgery (SBACV), based on VTE risk classification. Results The overall rate of correctly-prescribed VTE prophylaxis was 42.1%, while 57.9% of patients were not managed correctly in this respect. Clinical patients had a 52.9% rate of appropriate prophylaxis, while the equivalent rate for surgical patients was 37.5%. Conclusions Rates of correctly-prescribed VTE prophylaxis are still lower than they should be. Ongoing education, measures to encourage bedside risk stratification, and improvements to the electronic prescription system could increase appropriate VTE prophylaxis rates


Subject(s)
Humans , Male , Female , Adult , Disease Prevention , Venous Thromboembolism/diagnosis , Hospitals, University , Thrombosis , Health Profile , Chronic Disease , Cross-Sectional Studies , Risk Factors , Venous Thrombosis , Embolism , Myocardial Infarction
3.
J. vasc. bras ; 16(4): f:314-l:319, out.-dez. 2017. ilus
Article in Portuguese | LILACS | ID: biblio-880798

ABSTRACT

O trombo venoso flutuante em veia femoral é um tipo de trombo com alto potencial de embolização pulmonar. Entretanto, ainda é controversa a conduta mais apropriada nesses casos. Tratamentos clínicos com anticoagulantes ou fibrinolíticos e trombectomias abertas ou por meio de dispositivos endovasculares vêm sendo empregados ainda sem um critério de indicação bem definido. Apresentamos três casos clínicos de trombos flutuantes em veia femoral, de etiologias distintas, cujos tratamentos e respectivas evoluções serão discutidos


A floating venous thrombus in the femoral vein is a type of thrombus with a high potential for pulmonary embolization. However, the most appropriate management for these cases is still controversial. Clinical treatments, using anticoagulants or fibrinolytics, open thrombectomies, or thrombectomies by means of endovascular devices have all been used, although the criteria for indication of each are not yet defined. We present 3 clinical cases of floating thrombi in femoral veins with different etiologies and discuss their respective treatments and outcomes


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Femoral Vein/surgery , Venous Thrombosis/surgery , Anticoagulants/therapeutic use , Enoxaparin/administration & dosage , Lower Extremity , Pulmonary Embolism , Therapeutics/methods , Thrombectomy/methods , Thrombosis/surgery , Ultrasonics/methods , Warfarin/administration & dosage
4.
Rev. Col. Bras. Cir ; 44(3): 308-313, mai.-jun. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-896583

ABSTRACT

RESUMO A termoablação endovascular das veias safenas insuficientes com laser é descrita como uma técnica menos invasiva, com resultados semelhantes à cirurgia convencional, porém, com efeitos adversos menos frequentes. A técnica de escleroterapia com espuma de polidocanol ecoguiada vem sendo empregada com a mesma finalidade. A combinação de técnicas pode representar uma alternativa para pacientes mais graves, como os portadores de úlcera varicosa. Um equipamento de laser (denominado VELAS) foi desenvolvido no Centro de Pesquisas em Ótica e Fotônica da USP-São Carlos em convênio com a FMB-UNESP para termoablação endoluminal da veia safena insuficiente. Neste estudo apresentamos os resultados preliminares do uso do aparelho de laser VELAS (diodo MMO 980nm) na termoablação endovascular de veias safenas insuficientes, em portadores de úlcera venosa crônica, associado à complementação com espuma de polidocanol para o tratamento de varicosidades, após uma semana. Os desfechos analisados foram o tempo de cicatrização da úlcera venosa, oclusão das veias tratadas e eventos adversos relacionados aos tratamentos. Foram incluídos 12 pacientes portadores de insuficiência de veia safena e úlcera venosa crônica que aceitaram participar do projeto. Todos foram tratados em regime ambulatorial, com anestesia local e termoablação da veia safena insuficiente (VELAS). Após uma semana da cirurgia, as varicosidades foram esclerosadas com polidocanol espuma (técnica de Tessari). O equipamento laser VELAS nacional apresentou fácil manuseio, oclusão venosa total em 83,3% dos pacientes (em sete dias) e a associação das técnicas foi responsável por uma taxa de cicatrização de feridas de 83,3%, sem ocorrência de eventos adversos.


ABSTRACT The endovenous laser ablation (EVLA) of the insufficient saphenous vein has similar results to open conventional surgery, but less morbidity. The echo-guided polidocanol foam sclerotherapy technique has been used for the same purpose. The combined techniques may play a role for more severe diseases, such as those with varicose ulcers. An EVLA device (called VELAS) has been developed in the Optics and Photonics Research Center of USP-São Carlos in agreement with FMB-UNESP. In this study, we present the preliminary results of the VELAS device (MMO 980nm diode) in patients with chronic venous ulcer, associated with echo-guided polidocanol foam sclerotherapy for the treatment of varicosities. Primary outcomes were healing time of the venous ulcer, occlusion of the treated veins and treatment-related adverse events. We included 12 patients with insufficient saphenous vein and chronic venous ulcer. Initially, we treated all of them with thermoablation of the insufficient saphenous vein (VELAS), on an outpatient basis, with local anesthesia. After one week of the procedure, we sclerosed the varicosities with polidocanol foam (Tessari technique). The national VELAS device was easily handled. Total venous occlusion occurred in 83.3% of the patients (in seven days) and the association of the techniques was responsible for a wound healing rate of 83.3%, with no adverse events.


Subject(s)
Humans , Male , Female , Adult , Aged , Polyethylene Glycols/therapeutic use , Saphenous Vein , Sclerosing Solutions/therapeutic use , Venous Insufficiency/therapy , Sclerotherapy , Laser Therapy , Lasers, Semiconductor/therapeutic use , Endovascular Procedures/methods , Severity of Illness Index , Brazil , Treatment Outcome , Combined Modality Therapy , Polidocanol , Middle Aged
5.
J. vasc. bras ; 15(4): 312-316, Oct.-Dec. 2016. graf
Article in Portuguese | LILACS | ID: biblio-841395

ABSTRACT

Resumo Infecções de sítios cirúrgicos com envolvimento de próteses sintéticas constituem grande desafio para tratamento. Apresentamos o caso de uma paciente com múltiplas comorbidades, histórico de enxerto aortobifemoral há 6 anos e reabordagem das anastomoses femorais por reestenoses há 5 anos. Apresentou dor inguinal esquerda e abaulamento súbitos com diagnóstico de pseudoaneurisma femoral roto e instabilidade hemodinâmica. Foi submetida a correção emergencial com interposição de prótese de dácron recoberta por prata e correção de grande hérnia incisional abdominal com tela sintética ao mesmo tempo. No pós-operatório, manteve-se por longo período sob terapia intensiva com dificuldade de extubação. Nesse ínterim, apresentou deiscência das suturas e fístula purulenta inguinal esquerda em contato com a prótese vascular. Optou-se pelo tratamento conservador, com desbridamento das feridas e aplicação de curativo a vácuo. A paciente evoluiu com melhora e cicatrização das feridas. Essa pode se constituir em ferramenta importante em casos similares.


Abstract Infections at the sites of surgery involving synthetic prostheses are challenging to treat. We present a case of a patient with multiple comorbidities who had undergone an aortobifemoral bypass 6 years previously and then re-intervention at the femoral anastomoses for restenosis 5 years previously. The patient presented with acute left inguinal pain and swelling and was diagnosed with a ruptured femoral pseudoaneurysm and hemodynamic instability. A repair was conducted by interposition of a silver-coated Dacron graft in the emergency room, and a large abdominal incisional hernia was repaired with synthetic mesh during the same intervention. After surgery, the patient remained intubated in intensive care for a long period. Meanwhile, she presented dehiscence of sutures and a left inguinal purulent fistula that was in contact with the vascular prosthesis. Conservative treatment was chosen, with debridement of wounds and vacuum therapy. The patient improved and the wounds healed. This could be an important tool in similar cases.


Subject(s)
Humans , Female , Aged , Aneurysm, False/diagnostic imaging , Femoral Artery/diagnostic imaging , Infection Control , Occlusive Dressings/adverse effects , Comorbidity , Lower Extremity
6.
J. vasc. bras ; 14(4): 351-355, out.-dez. 2015. tab, graf
Article in English | LILACS | ID: lil-767714

ABSTRACT

A Doença de Behçet é uma doença inflamatória caracterizada por úlceras genitais e orais recorrentes, uveítes e lesões cutâneas. O envolvimento arterial é raro, sendo mais comuns as degenerações aneurismáticas do que as oclusivas. Neste caso clínico, paciente do sexo feminino, em tratamento de doença de Behçet havia 20 anos, iniciou com dor abdominal progressiva por dois meses, com piora súbita importante, foi submetida à tomografia computadorizada, que mostrou pseudoaneurisma toracoabdominal. A paciente foi submetida a tratamento endovascular com sucesso.


Behçet’s disease is an inflammatory disease characterized by recurrent oral and genital ulcers, uveitis and skin lesions. Arterial involvement is rare, but when present aneurysmal degeneration is more common than occlusive disease. This report describes the clinical case of a female patient who had been receiving treatment for Behçet’s disease for twenty years before presenting with abdominal pain that progressed for 2 months before suddenly worsening significantly. A CT scan revealed a thoracoabdominal pseudoaneurysm. She was successfully treated with endovascular repair.


Subject(s)
Humans , Female , Adult , Aneurysm, False/rehabilitation , Endovascular Procedures/rehabilitation , Behcet Syndrome/diagnosis , Behcet Syndrome/rehabilitation , Behcet Syndrome , Prednisone/administration & dosage , Tomography, X-Ray Computed/methods
7.
J. vasc. bras ; 13(4): 318-324, Oct-Dec/2014. graf
Article in English | LILACS | ID: lil-736014

ABSTRACT

Endovascular aneurysm repair (EVAR) is already considered the first choice treatment for abdominal aortic aneurysms (AAA). Several different strategies have been used to address limitations to arterial access caused by unfavorable iliac artery anatomy. The aim of this report is to illustrate the advantages and limitations of each option and present the results of using the internal endoconduit technique and the difficulties involved.


O tratamento endovascular para aneurisma de aorta abdominal (AAA) já está bastante difundido, sendo considerado como primeira escolha na maioria dos casos. Limitações no acesso pelas artérias ilíacas tortuosas, com estenoses, calibre pequeno ou doença oclusiva já foram contornadas com o uso de condutos, dissecção direta aortoilíaca, angioplastias, entre outros procedimentos. O objetivo deste desafio é mostrar as vantagens e limitações de cada alternativa, além de apresentar o resultado e as dificuldades com o endoconduíte.


Subject(s)
Humans , Female , Middle Aged , Aortic Aneurysm, Abdominal/surgery , Endovascular Procedures/methods , Iliac Artery/anatomy & histology , Endarterectomy , Endovascular Procedures/instrumentation
8.
J. vasc. bras ; 13(3): 235-243, Jul-Sep/2014. graf
Article in English | LILACS | ID: lil-727127

ABSTRACT

Endovascular treatment of abdominal aortic aneurysms (AAA), involving the exits of the renal and visceral arteries still constitutes a considerable challenge. Many different techniques have been developed over the years in attempts to surmount the difficulties presented by these cases. Techniques that have gained prominence include fenestrated or branched stents, methods involving parallel prostheses, such as the chimney, periscope and sandwich techniques, and, more recently, flow modulation with Multilayer stents. We describe a case of a complex juxtarenal saccular AAA with a high surgical risk, both according to cardiological assessment and because the patient had a difficult airway caused by a total laryngectomy for early stage laryngeal neoplasm. In view of the technical simplicity of using Multilayer stents, the presence of chronic obstructive aortoiliac disease, ostial stenosis of the renal artery and a small diameter suprarenal aorta, options involving fenestrated/branched stents and techniques involving parallel prostheses were ruled out, because of the need for multiple accesses. In view of the dilemma it presented, we describe this case as a therapeutic challenge and present the treatment option employed, which has been successful over the short term...


O tratamento endovascular de aneurismas de aorta abdominal (AAA), envolvendo a saída das artérias renais e viscerais, constitui ainda um importante desafio. Diversas técnicas foram desenvolvidas ao longo do tempo para contornar as dificuldades oferecidas por esta situação, destacando-se as endopróteses fenestradas ou ramificadas, as técnicas envolvendo próteses paralelas, como Chaminé, Periscópio e Sanduíche, e, mais recentemente, a utilização da modulação de fluxo por stent multicamadas Multilayer. Apresentamos um caso de AAA sacular complexo justarrenal e com alto risco cirúrgico pela avaliação cardiológica e por apresentar via aérea difícil, em decorrência de laringectomia total por antecedente de neoplasia de laringe. Devido à facilidade técnica do uso do Multilayer, à presença de doença obstrutiva crônica aorto-ilíaca, à estenose ostial renal e ao diâmetro limitado da aorta suprarrenal, descartaram-se as opções envolvendo endopróteses fenestradas/ramificadas ou técnicas envolvendo próteses paralelas, pela necessidade de diversos acessos para a execução. Diante do dilema imposto, apresentamos este caso como desafio terapêutico e com uma opção de tratamento bem sucedida, em curto prazo...


Subject(s)
Humans , Male , Aged , Aortic Aneurysm, Abdominal/therapy , Aortic Aneurysm, Abdominal , Endovascular Procedures/rehabilitation , Echocardiography, Doppler , Tomography
SELECTION OF CITATIONS
SEARCH DETAIL